DocumentCode :
2681410
Title :
Detect GGO Nodule Based on Dot Filter
Author :
Sun, Shenshen ; Gu, Wenjuan ; Fan, Linan ; Ren, Huizhi
Author_Institution :
Inf. Eng. Coll., Shenyang Univ. Shenyang, Shenyang, China
fYear :
2012
fDate :
28-30 May 2012
Firstpage :
765
Lastpage :
767
Abstract :
Aiming at solving the problem that the dot-filter can not detect ground-glass-opacity nodules, a method based on an adaptive nonlinear filter and dot filter was used to detect them. Experiments were performed at 23 scans of CT images (containing 32 GGO nodule). The sensitivity of the detection method was 84.4%. The time cost was 1.2 minutes per scan. This new method is superior to existing methods on the required time and sensitivity.
Keywords :
adaptive filters; cancer; computerised tomography; medical image processing; nonlinear filters; object detection; CT image; GGO nodule detection; adaptive nonlinear filter; computerised tomography; detection method sensitivity; dot filter; ground-glass-opacity nodule; lung cancer; Biomedical imaging; Cancer; Computed tomography; Educational institutions; Gabor filters; Lungs; Nonlinear filters; adaptive nonlinear filter; dot-filter; ground-glass-opacity; nodule detection;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Engineering and Biotechnology (iCBEB), 2012 International Conference on
Conference_Location :
Macau, Macao
Print_ISBN :
978-1-4577-1987-5
Type :
conf
DOI :
10.1109/iCBEB.2012.129
Filename :
6245232
Link To Document :
بازگشت