  • Abstract
    This paper describes the principle of operation of electromagnetic inductance tomography and a parallel field EMT system. Some recent research activities are also discussed
  • Keywords
    computerised monitoring; computerised tomography; electric sensing devices; image reconstruction; inductance measurement; process control; 100 kHz; biomedical imaging; computerised tomography; electromagnetic inductance tomography; image reconstruction; industrial applications; mutual inductance tomography; parallel field EMT system; principle of operation; process tomography; twin coil;