DocumentCode
270772
Title
Measurement of ground currents leaking from DC electric traction
Author
KolaÌrÌŒ, VaÌclav ; HrbaÌcÌŒ, Roman
Author_Institution
Fac. of Electr. Eng. & Comput. Sci., VSB-TU Ostrava, Ostrava, Czech Republic
fYear
2014
fDate
12-14 May 2014
Firstpage
613
Lastpage
617
Abstract
This paper deals with measurement of stray currents caused by electric tramways. Stray currents can significantly contribute to corrosion of metal devices buried underground. This paper focuses on measurement of currents leaking into the ground from a tramway track. It describes Ohm´s method based measurement method, measuring apparatus and a device that is used to determine rail resistance as well as an actual measurement on a tramway track.
Keywords
electric current measurement; electric resistance; leakage currents; railway rolling stock; traction; DC electric traction; Ohms method based measurement method; electric tramway track; leakage ground current measurement; measuring apparatus; metal devices corrosion; rail resistance; stray current; Battery charge measurement; Current measurement; Electrical resistance measurement; Rails; Resistance; Substations; Voltage measurement; electric traction; measurement; stray currents;