• DocumentCode
    273636
  • Title

    Redundant, fault-tolerant control system for a 13 MW high speed drive

  • Author

    Steimer, P.K.

  • Author_Institution
    ASEA Brown Boveri, Baden, Switzerland
  • fYear
    1988
  • fDate
    13-15 Jul 1988
  • Firstpage
    343
  • Lastpage
    346
  • Abstract
    Variable speed drives in chemical and petrochemical plants need a high reliability and availability. Therefore redundancy is often realized in the power converter and other subsystems. For the control electronics an interesting solution may be a redundant, fault-tolerant control system, which can reduce the probability of an outage by a factor ten. An additional man machine communication system with comfortable help information in connection with a modular control system can reduce the repair time of a failed control, while the drive remains in operation on the other control channel. The author develops this concept which is based on experience gained by Asea Brown Boveri
  • Keywords
    power convertors; redundancy; reliability; variable speed gear; 13 MW; control electronics; fault-tolerant control system; man machine communication system; modular control system; petrochemical plants; power converter; redundancy; reliability; variable speed drives;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Power Electronics and Variable-Speed Drives, Third International Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-85296-364-5
  • Type

    conf

  • Filename
    23383