Abstract
Variable speed drives in chemical and petrochemical plants need a high reliability and availability. Therefore redundancy is often realized in the power converter and other subsystems. For the control electronics an interesting solution may be a redundant, fault-tolerant control system, which can reduce the probability of an outage by a factor ten. An additional man machine communication system with comfortable help information in connection with a modular control system can reduce the repair time of a failed control, while the drive remains in operation on the other control channel. The author develops this concept which is based on experience gained by Asea Brown Boveri
Keywords
power convertors; redundancy; reliability; variable speed gear; 13 MW; control electronics; fault-tolerant control system; man machine communication system; modular control system; petrochemical plants; power converter; redundancy; reliability; variable speed drives;