DocumentCode
274241
Title
The importance of complete drive train analysis for brushless salient pole motor drives
Author
Williams, P.N. ; McQuin, N.P. ; Buckland, J.E.
Author_Institution
Brush Electr. Machines Ltd., Loughborough, UK
fYear
1989
fDate
13-15 Sep 1989
Firstpage
210
Lastpage
214
Abstract
It is important that a shaft train torsional analysis is carried out for all systems driven by synchronous motors. During starting, either by direct on-line or by using a variable frequency supply, the motor generates oscillatory air gap torques which excite a torsional response throughout the shaft system. The authors show that by implementing a torsional response study for a salient pole motor at an early stage in the design of a shaft system, high oscillatory torques can be avoided
Keywords
electric drives; synchronous motors; torque; brushless salient pole motor drives; oscillatory air gap torques; shaft train torsional analysis; synchronous motors; torsional response study;
fLanguage
English
Publisher
iet
Conference_Titel
Electrical Machines and Drives, 1989. Fourth International Conference on (Conf. Publ. No. ??)
Conference_Location
London