• DocumentCode
    274241
  • Title

    The importance of complete drive train analysis for brushless salient pole motor drives

  • Author

    Williams, P.N. ; McQuin, N.P. ; Buckland, J.E.

  • Author_Institution
    Brush Electr. Machines Ltd., Loughborough, UK
  • fYear
    1989
  • fDate
    13-15 Sep 1989
  • Firstpage
    210
  • Lastpage
    214
  • Abstract
    It is important that a shaft train torsional analysis is carried out for all systems driven by synchronous motors. During starting, either by direct on-line or by using a variable frequency supply, the motor generates oscillatory air gap torques which excite a torsional response throughout the shaft system. The authors show that by implementing a torsional response study for a salient pole motor at an early stage in the design of a shaft system, high oscillatory torques can be avoided
  • Keywords
    electric drives; synchronous motors; torque; brushless salient pole motor drives; oscillatory air gap torques; shaft train torsional analysis; synchronous motors; torsional response study;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1989. Fourth International Conference on (Conf. Publ. No. ??)
  • Conference_Location
    London
  • Type

    conf

  • Filename
    55393