DocumentCode :
2744177
Title :
Bilateral comparison on calibration factor of a 2.92 mm power sensor
Author :
Yhland, Klas ; Judaschke, Rolf ; Rausche, Florian ; Wingqvist, Claes ; Stenarson, Jörgen
Author_Institution :
SP Tech. Res. Inst. of Sweden, Boras, Sweden
fYear :
2012
fDate :
1-6 July 2012
Firstpage :
86
Lastpage :
87
Abstract :
This paper describes a bilateral comparison between PTB and SP on the calibration factor of a 2.92 mm thermocouple power sensor. The measurements were done at 0 dBm from 50 MHz to 40 GHz. The comparison also covers the sensor reflection coefficient over the same frequency range.
Keywords :
calibration; microwave measurement; power measurement; sensors; thermocouples; PTB; SP; calibration factor; frequency 50 MHz to 40 GHz; sensor reflection coefficient; size 2.92 mm; thermocouple power sensor; Calibration; Laboratories; Measurement uncertainty; Microwave measurements; Reflection; Standards; Uncertainty; 2.92 mm; Measurement comparison; calibration factor; measurement uncertainty; microwave; power sensor; reflection coefficient;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location :
Washington, DC
ISSN :
0589-1485
Print_ISBN :
978-1-4673-0439-9
Type :
conf
DOI :
10.1109/CPEM.2012.6250673
Filename :
6250673
Link To Document :
بازگشت