DocumentCode
2749044
Title
Methods for comparison of loss angle standards at 10 kV level
Author
Hällström, J. ; Klionsky, M. ; Suomalainen, E.-P.
Author_Institution
MIKES, Espoo, Finland
fYear
2012
fDate
1-6 July 2012
Firstpage
402
Lastpage
403
Abstract
Comparison of loss angle measurements and measurement techniques at power frequency up to 10 kV are presented. The loss angle standards developed by VNIIM are based on low loss ceramic capacitors with a detachable loss resistor in series with it. The tand values of the studied standards ranged from - 1·10-4 to 1000·10-4. The loss angle standards were characterized using established references at VNIIM and MIKES.
Keywords
ceramic capacitors; frequency measurement; loss measurement; measurement standards; power measurement; power system measurement; resistors; MIKES; VNIIM; detachable loss resistor; loss angle measurement; loss angle standard; low loss ceramic capacitors; power frequency measurement; voltage 10 kV; Bridge circuits; Capacitance; Capacitors; Current measurement; Loss measurement; Standards; Uncertainty; Capacitance; high-voltage techniques; loss measurement; measurement standards; uncertainty;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
Conference_Location
Washington, DC
ISSN
0589-1485
Print_ISBN
978-1-4673-0439-9
Type
conf
DOI
10.1109/CPEM.2012.6250973
Filename
6250973
Link To Document