On-site transformer partial discharge diagnosis
Author :
Gross, Detlev W. ; Soeller, Markus
Author_Institution :
Power Diagnostix Syst. GmbH, Aachen, Germany
fYear :
2012
fDate :
10-13 June 2012
Firstpage :
558
Lastpage :
564
Abstract :
In the lab, partial discharge diagnosis has widely replaced the traditional RIV measurements. Additionally, partial discharge acceptance levels are being reduced due to the increasing use of composite material and a growing awareness of partial discharge phenomenon and their consequences. Adequate filtering of the supply voltage for induced voltage testing and the use of sensitive acoustic measurement has greatly improved the detection and location of partial discharge activity in power transformers. An increasing population of service aged substation equipment having reached their projected service life demands on-site repair and, hence, on-site testing to factory standards. Using inverter based three-phase mobile test sets allows on-site application of tests previously limited to a mere test room environment. Besides the unmatched portability of inverter-based sources, especially the less critical generation of reactive power simplifies on-site testing, if compared with motor-generator sets. Additionally, the lack of high short circuit currents limits the damage in case of breakdown. However, adequately removing the switching noise spectrum becomes a demanding task in order to reach the required sensitivity of the partial discharge measurements.
Keywords :
acoustic measurement; maintenance engineering; partial discharge measurement; power transformer testing; transformer substations; RIV measurements; acoustic measurement; composite material; factory standards; induced voltage testing; inverter-based three-phase mobile test sets; motor-generator sets; onsite repair; onsite testing; onsite transformer partial discharge diagnosis; partial discharge acceptance levels; partial discharge activity detection; partial discharge activity location; partial discharge measurement sensitivity; power transformers; reactive power; service aged substation equipment; service life; short circuit currents; supply voltage filtering; switching noise spectrum; Inverters; Mobile communication; Noise; Partial discharges; Power transformer insulation; Testing; acoustic location; diagnosis; inverter-based; on-site; partial discharge;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation (ISEI), Conference Record of the 2012 IEEE International Symposium on
Conference_Location :
San Juan, PR
ISSN :
1089-084X
Print_ISBN :
978-1-4673-0488-7
Electronic_ISBN :
1089-084X
Type :
conf
DOI :
10.1109/ELINSL.2012.6251532
Filename :
6251532
Link To Document :
بازگشت