• DocumentCode
    276334
  • Title

    An unambiguous technique for displaying the presence of stator winding faults in induction motors

  • Author

    Penman, J. ; Yin, C.M.

  • Author_Institution
    Aberdeen Univ., UK
  • fYear
    1991
  • fDate
    11-13 Sep 1991
  • Firstpage
    51
  • Lastpage
    55
  • Abstract
    It has been shown that the occurrence of shorted turns and phase imbalanced in the stator winding of induction motors cause predictable harmonics to appear in the spectrum of line currents and in the axial leakage flux. The authors show how such beating can itself be used as a measure of condition of the machine. The proposed technique extracts the changes in phase caused by the beat frequencies, and uses them to develop an alternative method of illustrating spectral changes. A simple computer based monitor has been developed using this technique, and results obtained using it are presented
  • Keywords
    automatic test equipment; automatic testing; fault location; harmonics; induction motors; machine testing; magnetic flux; magnetic leakage; stators; automatic testing; axial leakage flux; beating; faults; harmonics; induction motors; line currents; machine testing; phase; phase imbalanced; shorted turns; stator winding;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1991. Fifth International Conference on (Conf. Publ. No. 341)
  • Conference_Location
    London
  • Print_ISBN
    0-85296-520-6
  • Type

    conf

  • Filename
    153963