DocumentCode :
2764395
Title :
Aggregation of induction motors based on their equivalent circuits under some special operating conditions
Author :
Louie, K.W.
Author_Institution :
Manitoba HVDC Res. Centre, Winnipeg, Man.
fYear :
2005
fDate :
1-4 May 2005
Firstpage :
1966
Lastpage :
1969
Abstract :
The paper presents a simple method for aggregating the three-phase single-cage-rotor induction motors connected to a common bus based on their equivalent circuits in power system studies. It is simple to aggregate the motors based on their equivalent circuits in certain operating states. The proposed method has been directly derived from the equivalent circuits of the motors at a same bus when their slips are unity and very small. The paper presents the derivation of the proposed technique and gives its verification
Keywords :
aggregation; equivalent circuits; induction motors; common bus; equivalent circuits; motors aggregation; three-phase single-cage-rotor induction motors; Aggregates; Damping; Equivalent circuits; Frequency; HVDC transmission; Induction motors; Power system dynamics; Power system modeling; Power systems; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Computer Engineering, 2005. Canadian Conference on
Conference_Location :
Saskatoon, Sask.
ISSN :
0840-7789
Print_ISBN :
0-7803-8885-2
Type :
conf
DOI :
10.1109/CCECE.2005.1557368
Filename :
1557368
Link To Document :
بازگشت