DocumentCode :
2799471
Title :
RIE of solenoidal microcoil glass mould with integrated sample container for micro-MRI
Author :
Klein, Mona J K ; Ono, T. ; Esashi, M. ; Korvink, J.G.
Author_Institution :
Univ. of Freiburg, Freiburg
fYear :
2007
fDate :
21-25 Jan. 2007
Firstpage :
345
Lastpage :
348
Abstract :
We report the fabrication of a solenoidal microcoil mould structure based on reactive ion etching (RIE) of 100 mum thick borosilicate glass wafers. For magnetic resonance imaging (MRI), glass has superior properties compared to silicon, e.g. the lower dielectric constant and transparency. Double-side polished substrates are pre-etched in a two step process, and then anodically bonded together to achieve a hollow structure inside the coil to serve as a sample container. Two additional etch steps that are each performed on the top and bottom surfaces of the bonded wafers complete the solenoidal coil mould structure.
Keywords :
borosilicate glasses; etching; magnetic resonance imaging; micromechanical devices; moulding; solenoids; wafer bonding; B2O3SiO2; RIE; bonded wafers; borosilicate glass wafers; double-side polished substrates; hollow structure; integrated sample container; magnetic resonance imaging; microMRI; reactive ion etching; size 100 mum; solenoidal microcoil glass mould; Coils; Containers; Dielectric constant; Etching; Fabrication; Glass; Magnetic properties; Magnetic resonance imaging; Silicon; Wafer bonding;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Micro Electro Mechanical Systems, 2007. MEMS. IEEE 20th International Conference on
Conference_Location :
Hyogo
ISSN :
1084-6999
Print_ISBN :
978-1-4244-095-5
Electronic_ISBN :
1084-6999
Type :
conf
DOI :
10.1109/MEMSYS.2007.4433106
Filename :
4433106
Link To Document :
بازگشت