Title :
A millimetre wave power transfer technique
Author_Institution :
RSRE, Great Malvern, UK
Abstract :
The techniques described involve the use of a multistate reflectometer. Calibration of the multistate is performed by attaching to the output port a series of short circuits and loads and the parameters of the calibration are found by processing the ratios of two power meters. Dealing in ratios, the system is effectively levelled and the quantity Gamma /sub g/, the effective reflection coefficient of the multistate reflectometer, is calculated as part of the calibration routine.<>
Keywords :
calibration; microwave reflectometry; calibration; effective reflection coefficient; microwave reflectometer; millimetre wave power transfer; multistate reflectometer; Calibration; Microwave reflectometry;
Conference_Titel :
What's New in Microwave Measurements (Digest No: 1990/174), IEE Colloquium on
Conference_Location :
London, UK