DocumentCode :
2809593
Title :
In situ monitoring of the degradation of insulating oil under AC voltage
Author :
Aka-Ngnui, T. ; Benounis, M. ; Jaffrezic-Renault, N. ; Stevenson, I. ; Beroual, A.
Author_Institution :
Ecole Centrale de Lyon, CEGELY-UMR CNRS, Ecully, France
fYear :
2005
fDate :
16-19 Oct. 2005
Firstpage :
253
Lastpage :
256
Abstract :
A method to follow the in situ ageing of transformer oil under operation is presented. It is based on the variation of the refractive index of oil due to the presence of gases resulting from partial discharges and that may lead to failure of transformer in the long term.
Keywords :
failure analysis; partial discharges; refractive index; transformer oil; ageing; insulating oil; partial discharges; refractive index; transformer oil; Aging; Degradation; Gases; Monitoring; Oil insulation; Partial discharges; Petroleum; Power transformer insulation; Refractive index; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2005. CEIDP '05. 2005 Annual Report Conference on
Print_ISBN :
0-7803-9257-4
Type :
conf
DOI :
10.1109/CEIDP.2005.1560669
Filename :
1560669
Link To Document :
بازگشت