• DocumentCode
    2810329
  • Title

    Based on physiology parameters to design lie detector

  • Author

    Zhiyu, Wang

  • Author_Institution
    Dept. of Commun. Technol., First Res. Inst. of Minist. of Public Security of RPC, Beijing, China
  • Volume
    8
  • fYear
    2010
  • fDate
    22-24 Oct. 2010
  • Abstract
    Objective - Multi-parameters are employed to design a device of lie detector, including Skin Temperature, electrocardiogram (ECG), Pressure of End-Tidal Carbon Dioxide (PETCO2), Oxygen Saturation and other physiological parameters. Methods: Skin Temperature is measured by temperature sensor, and it is used to monitor the difference during the lie detection procedure. Standard CM5 ECG lead, used to extract the signal of heart rate, re-extracted heart rate variability and other autonomic nervous system characterized by the parameters. Oxygen Saturation and PETCO2 detection were tested late changes of respiration and respiratory status. 300Hz sampling rate was used to capture the channel signal. Through the low-power microcontroller MSP430, the signal was sent into computer via USB communication. Result: After debugging and verifying, reliable physical parameters can be collected from multi-parameter detection system. It provided a set of physiological information monitoring for the hardware system. Discussion: Signal analysis software needed further design, at the same time adjust the acquisition parameters of front-end signal, and a reasonable configuration, all of them are lay the foundation of software system design. The result shows that the lie detector system based on physiological parameters is cheaper and more convenient than others.
  • Keywords
    behavioural sciences computing; electrocardiography; medical signal processing; physiological models; ECG; PETCO2; USB communication; acquisition parameters; channel signal; design lie detector; electrocardiogram; front end signal; hardware system; heart rate signal; low power microcontroller; multiparameter detection system; oxygen saturation; physiological information monitoring; physiological parameters; physiology parameters; pressure of end-tidal carbon dioxide; respiratory status; signal analysis software; skin temperature; temperature sensor; Converters; Electrocardiography; Electrodes; Lead; Microcomputers; Psychology; Universal Serial Bus; lie detector; physiology parameters; signal processing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer Application and System Modeling (ICCASM), 2010 International Conference on
  • Conference_Location
    Taiyuan
  • Print_ISBN
    978-1-4244-7235-2
  • Electronic_ISBN
    978-1-4244-7237-6
  • Type

    conf

  • DOI
    10.1109/ICCASM.2010.5619088
  • Filename
    5619088