DocumentCode :
2813800
Title :
Investigation of acquisition parameters for PVI normalization
Author :
Kohlmyer, S.G. ; Kaplan, M.S. ; Lewellen, T.K.
Author_Institution :
Dept. of Radiol., Washington Univ., Seattle, WA, USA
Volume :
2
fYear :
1997
fDate :
9-15 Nov 1997
Firstpage :
1328
Abstract :
The authors studied the effects of count density, count rate, and source geometry on a model based normalization using a GE Advance PET system. To study precision vs. count density the authors generated crystal efficiencies, ε, from 20 time equivalent PVI scans acquired with a 50 μCi rotating 68Ge line source, and calculated the standard deviation, σ, of the individual ε over the 20 realizations. The σ followed the Poisson estimate of 1/√N where N is the total number of counts involving a given crystal. For example, an average value of 2.7 counts per line of response in the central 22 cm field of view resulted in 5,000 counts per crystal and a σ of 1.5%. Using a 20 cm cylinder filled with F-18, the authors studied count rate effects by measuring the difference between ε generated from acquisitions ranging in block deadtime (BDT) from 0.6% to 11.4% and those from a low rate, high count reference scan. Rate induced errors increased linearly from 0.5% to 4.8% over the 1.2% to 11.4% BDT range. The authors studied cylinder, annulus (20 cm OD and 14 cm ID), and rotating rod 68Ge source geometries. Eight sets of ε were generated for each geometry, and compared cylinder to annulus and cylinder to rotating rod using the Student´s t statistic. Elliptical phantom data were normalized by each source geometry and reconstructed using 3DRP
Keywords :
data acquisition; positron emission tomography; 14 cm; 20 cm; 22 cm; 5E-5 ci; F; F-18; GE Advance PET system; Ge; PVI normalization; Student´s t statistic; acquisition parameters; block deadtime; count density; count rate; crystal efficiency; elliptical phantom data; medical diagnostic imaging; model based normalization; nuclear medicine; positron volume imaging; rate induced errors; rotating rod 68Ge source; source geometry; Computed tomography; Density measurement; Detectors; Geometry; Imaging phantoms; Interference; Positron emission tomography; Radiology; Solid modeling; Statistics;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium, 1997. IEEE
Conference_Location :
Albuquerque, NM
ISSN :
1082-3654
Print_ISBN :
0-7803-4258-5
Type :
conf
DOI :
10.1109/NSSMIC.1997.670566
Filename :
670566
Link To Document :