DocumentCode
283862
Title
Radiometric instrumentation for plant environmental monitoring at BNFL Sellafield
Author
Proud, N.J. ; Finlayson, A.J. ; Pearce, R.T.
Author_Institution
British Nuclear Fuels Lab., London, UK
fYear
1992
fDate
33914
Firstpage
42522
Lastpage
615
Abstract
BNFL has detailed experience and knowledge in the application of installed radiometric instrumentation, primarily at Sellafield. The range of applications is extensive and comprises: (i) process monitoring; (ii) waste characterisation; (iii) fissile material accountancy; (iv) environmental discharge monitoring; (v) workplace monitoring. The scale of the systems ranges from single stand alone instruments to large building surveillance and evacuation systems incorporating many airborne contamination monitors. Over 600 alpha-in-air monitors, 1000beta-in-air monitors and 500gamma monitors have been installed in 30 new plants at Sellafield since 1975
Keywords
alpha-particle detection and measurement; beta-ray detection and measurement; gamma-ray detection and measurement; nuclear materials safeguards; radiation monitoring; radiometers; alpha detector; alpha-in-air monitors; beta detector; beta-in-air monitors; environmental discharge monitoring; fissile material accountancy; gamma detector; gamma monitors; process monitoring; waste characterisation; workplace monitoring;