• DocumentCode
    2845299
  • Title

    Investigation on Operating Characteristics of Individual Cells in a Lead-Acid Battery Pack

  • Author

    Hsieh, Yao C. ; Chen, Wen C. ; Ng, Kong S. ; Moo, Chin S.

  • Author_Institution
    Nat. Dong Hwa Univ., Hualien
  • fYear
    2007
  • fDate
    2-5 April 2007
  • Firstpage
    745
  • Lastpage
    750
  • Abstract
    Similar to series-connected batteries, series-connected cells in a battery pack also suffer from the perplexity of unbalanced voltage while charging or discharging processes, especially for lead-acid batteries. This paper is to study the impact on capacity reduction under different operation conditions, such as different float-charging voltages, different cut-off discharging voltages and even discharging to negative voltages. The results reveal that the health of battery cells is more significantly affected by float-charging voltage than by the discharging cut-off voltage. However, discharging a cell into exceedingly negative voltage incurs a destructive consequence. A bypass protection circuit is proposed to mitigate the deterioration rate of battery cells. Experimental results show that the capacity reduction rate can be decreased distinctly.
  • Keywords
    lead acid batteries; protection; bypass protection circuit; capacity reduction rate; charging processes; cut-off discharging voltages; discharging processes; float-charging voltages; lead-acid battery pack; series-connected batteries; series-connected cells; unbalanced voltage; Aging; Batteries; Breakdown voltage; Circuits; Councils; Diodes; Lead; Protection; Turning; Wires; bypass protection; cell; cut-off voltage; float-charging; lead-acid battery;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Conversion Conference - Nagoya, 2007. PCC '07
  • Conference_Location
    Nagoya
  • Print_ISBN
    1-4244-0844-X
  • Electronic_ISBN
    1-4244-0844-X
  • Type

    conf

  • DOI
    10.1109/PCCON.2007.373050
  • Filename
    4239240