• DocumentCode
    2847338
  • Title

    Gamma ray damage of biased CCD image sensors

  • Author

    Vrba, Radimir

  • fYear
    2005
  • fDate
    5-7 Sept. 2005
  • Firstpage
    173
  • Lastpage
    175
  • Abstract
    High image quality CCD image sensors are needed in many applications. Low noise and high dynamic range are critical parameters required in scientific and industrial applications. In many of the applications, however, the CCD image sensor can be irradiated by an ionizing radiation, as alpha, beta, gamma or X-ray. This paper shows behaviour of low noise, high dynamic range, 1 megapixel frame transfer CCD FTT1010-M image sensor radiated by gamma ray radiation. CCD image sensor driver board with rad-hard components was designed and used during the tests. Results of the investigation will be used in system for protein crystallization study in microgravity.
  • Keywords
    CCD image sensors; biological techniques; crystallisation; gamma-ray effects; molecular biophysics; proteins; X-ray; alpha ray; beta ray; biased CCD image sensors; frame transfer CCD FTT1010-M image sensor; gamma ray; gamma ray damage; ionizing radiation; microgravity; protein crystallization; Charge coupled devices; Charge-coupled image sensors; Dynamic range; Image quality; Image sensors; Ionizing radiation; Proteins; Radiation hardening; Testing; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Sensors and the International Conference on new Techniques in Pharmaceutical and Biomedical Research, 2005 Asian Conference on
  • Print_ISBN
    0-7803-9370-8
  • Type

    conf

  • DOI
    10.1109/ASENSE.2005.1564533
  • Filename