DocumentCode
2852901
Title
Working regions of adjustable-speed units with doubly fed machines
Author
Schreier, L. ; Chomát, M. ; Bendl, J.
Author_Institution
Inst. of Electr. Eng., Czechoslovak Acad. of Sci., Prague, Czech Republic
fYear
1999
fDate
36281
Firstpage
457
Lastpage
459
Abstract
The working regions of an adjustable-speed generation unit with a doubly fed machine connected to the power grid are determined. The analytical relations for the control range of the rotor voltage phasor due to the maximal permissible values of currents and voltages of the machine and supply cycloconverter are presented. Simulation results are shown to illustrate the operation of the system
Keywords
AC generators; cycloconvertors; machine control; rotors; variable speed gear; voltage control; AC machines; adjustable-speed generation unit; adjustable-speed units; doubly fed machines; power grid; rotor voltage phasor control; supply cycloconverter; working regions; Design for manufacture; Energy efficiency; Equations; Mesh generation; Power generation; Power grids; Reactive power; Stators; Turbines; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Machines and Drives, 1999. International Conference IEMD '99
Conference_Location
Seattle, WA
Print_ISBN
0-7803-5293-9
Type
conf
DOI
10.1109/IEMDC.1999.769145
Filename
769145