Abstract
The world´s largest adjustable speed synchronous motor drive system is now operational at NASA´s National Transonic Facility (wind tunnel). The successful activation of this newly installed system was achieved through structured factory tests and a comprehensive commissioning plan. Data from the commissioning tests are presented. The tests validate the design, characterize the operational envelope, and demonstrate that performance requirements were met
Keywords
commissioning; synchronous motor drives; variable speed drives; wind tunnels; 135000 hp; NASA; National Transonic Facility; adjustable speed drive; commissioning plan; commissioning requirements; commissioning results; commissioning tests; operational experience; performance requirements; structured factory tests; synchronous motor drive; wind tunnel; Conductors; Current transformers; Job shop scheduling; NASA; Nitrogen; Performance evaluation; Production facilities; Synchronous motors; System testing; Variable speed drives;