• DocumentCode
    2855181
  • Title

    The use of magnetic fields to improve photon dose distributions for radiation therapy-a possible approach to “poor man´s proton” beam properties

  • Author

    Chu, J.C.H. ; Reiffe, L. ; Naqvi, S. ; Li, X.A. ; Ye, S.-J. ; Saxena, A.

  • Author_Institution
    Depts. of Med. Phys. & Radiat. Oncology, Rush Presbyterian St. Luke´´s Med. Center, Chicago, IL, USA
  • Volume
    4
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    2737
  • Abstract
    Several researchers have proposed the use of magnetic fields to modify the dose distributions for electron beams over the past 50 years. However, the potential use of magnetic fields to improve the dose distributions produced by X-ray beams has been largely ignored due to the conventional paradigm that magnetic fields are not expected to affect the behavior of uncharged radiations like X-rays and neutrons. This assumption is not necessarily valid. The authors have studied the effect of intense locally applied transverse magnetic fields on X-ray dose distributions for various beam energies, field sizes, and magnetic field strengths using Monte Carlo simulation. Significant dose enhancement is found close to the proximal magnetic field gradient region due to the prevention of secondary electrons from traveling downstream; whereas significant dose reduction is observed close to the distal gradient due to the need for re-establishment of the secondary electronic build-up region. The degree of dose enhancement and reduction along the central axis of the beam can be up to 100% and 60% respectively under idealized conditions. The isodose distributions for realistic magnetic fields also show lateral shifts of the electron dose deposition patterns. The authors´ preliminary data show that a transversely applied magnetic field is capable of producing controllable and almost proton-like dose peaks in addition to dose dips in X-ray beams. This magnetic field induced dose modulation has the potential under certain circumstances of increasing the dose to the target volume and reducing the dose to the adjacent normal tissues in photon radiation therapy
  • Keywords
    Monte Carlo methods; X-ray applications; dosimetry; magnetic fields; radiation therapy; 50 y; Monte Carlo simulation; X-ray beams; X-ray dose distributions; adjacent normal tissues; beam energies; distal gradient; dose dips; dose enhancement; field sizes; intense locally applied transverse magnetic fields; magnetic field strengths; photon dose distributions improvement; proximal magnetic field gradient region; secondary electronic build-up region; secondary electrons; uncharged radiations behavior; Biomedical applications of radiation; Cancer; Electron beams; Intensity modulation; Magnetic fields; Magnetic modulators; Magnetic properties; Neutrons; Optical modulation; Particle beams;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-6465-1
  • Type

    conf

  • DOI
    10.1109/IEMBS.2000.901426
  • Filename
    901426