• DocumentCode
    2856771
  • Title

    Demonstration of correlations between physical and clinical image quality measures in chest and lumbar spine radiography

  • Author

    Sandborg, Michael ; Tingberg, Anders ; Sund, Patrik ; McVey, Graham ; Dance, David ; Carlsson, Gudrun Alm

  • Author_Institution
    Div. of Radiat. Phys., Linkoping Univ., Sweden
  • Volume
    4
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    3078
  • Abstract
    Clinical and physical assessments of image quality are compared and the correlation between the two derived. Clinical assessment has been made by a group of expert radiologists who evaluated the fulfillment of the European Image Criteria for chest and lumbar spine radiography; yielding the so-called Image Criteria Score, ICS. Physical measures of image quality were calculated using a Monte Carlo model of the complete imaging system. This model includes a voxelised male anatomy and calculates contrast and signal-to-noise ratio of various anatomical details and a measure of useful dynamic range. Correlations between the ICS and the physical image quality measures were sought. Four lumbar spine and 16 chest imaging systems were evaluated and simulated with the model. The most useful physical quantities for chest radiography were the dynamic range and contrast of blood vessels in the retro-cardiac area. In lumbar spine, it was the signal-to-noise ratio of trabecular structures. The significant correlation is encouraging and shows that clinical image quality can be predicted provided the imaging conditions are well known and that relevant measures of physical image quality are used to assess the quality of the image
  • Keywords
    Monte Carlo methods; diagnostic radiography; orthopaedics; quality control; European Image Criteria; Image Criteria Score; anatomical details; chest radiography; clinical image quality measures; contrast; lumbar spine radiography; medical diagnostic imaging; physical image quality measures; signal-to-noise ratio; useful dynamic range; voxelised male anatomy; Anatomy; Diagnostic radiography; Dynamic range; Image quality; Monte Carlo methods; Optical devices; Optical imaging; Signal to noise ratio; Spine; Visualization;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
  • Conference_Location
    Chicago, IL
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-6465-1
  • Type

    conf

  • DOI
    10.1109/IEMBS.2000.901532
  • Filename
    901532