DocumentCode :
286526
Title :
High bandwidth measurement of SRM torque ripple
Author :
Schramm, D.S. ; Williams, B.W.
Author_Institution :
Heriot-Watt Univ., Edinburgh, UK
fYear :
1993
fDate :
8-10 Sep 1993
Firstpage :
647
Lastpage :
651
Abstract :
An indirect SRM torque measurement technique is proposed which has the features of high bandwidth, low noise, no timing errors, and free from shaft mechanical oscillations. Differences between static and dynamic torque production are the technique´s main source of error. Offline measurement of static torque characteristics is required by the proposed measurement technique which evaluates the real time torque production from measured phase currents in association with an interpolation algorithm. Test results of the novel six switch 4 kW, IGBT, 20 kHz inverter bridge used to current feed the four phase 4 kW switched reluctance motor are shown. A torque ripple reduction method which minimizes both the average and the peak current, evaluated from the high bandwidth torque measurement technique, is also presented
Keywords :
machine testing; oscillations; reluctance motors; switching circuits; torque measurement; 20 kHz; 4 kW; IGBT; SRM; error; four phase; high bandwidth; interpolation algorithm; inverter; machine testing; phase currents; power transistors; real time; static torque characteristics; switched reluctance motors; torque measurement; torque ripple;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Electrical Machines and Drives, 1993. Sixth International Conference on (Conf. Publ. No. 376)
Conference_Location :
Oxford
Print_ISBN :
0-85296-596-6
Type :
conf
Filename :
253503
Link To Document :
بازگشت