Title :
RF feed-forward control experiments for the 50 MeV linear accelerator at TLS
Author :
Hu, K.H. ; Wu, C.Y. ; Lee, Demi ; Hsu, K.T. ; Lin, K.K. ; Hwang, J.Y.
Author_Institution :
NSRRC, Hsinchu
Abstract :
Performance of an electron linear accelerator is very important for synchrotron light source application. Its performance will determine the reproducibility of filling pattern in the booster synchrotron. The filling pattern of the booster synchrotron will then affect filling pattern control of the storage ring. The RF feed-forward control can effectively improve performance of linear accelerator. Design consideration and details of the implementation will be summarized in this report.
Keywords :
accelerator RF systems; accelerator control systems; linear accelerators; RF feed-forward control experiments; electron linear accelerator; linear accelerator; Demodulation; Feedforward systems; Filling; Gallium arsenide; Klystrons; Linear accelerators; Radio frequency; Radiofrequency amplifiers; Solenoids; Synchrotrons;
Conference_Titel :
Particle Accelerator Conference, 2007. PAC. IEEE
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0916-7
DOI :
10.1109/PAC.2007.4439990