• DocumentCode
    2884019
  • Title

    Thermal Management of Active Electronically Scanned Array Transmit/Receive LRU (Line Replaceable Unit)

  • Author

    Pluymers, Brian A. ; Reese, Robert M.

  • Author_Institution
    Lockheed Martin Maritime Syst. & Sensors, Moorestown
  • fYear
    2007
  • fDate
    17-20 April 2007
  • Firstpage
    150
  • Lastpage
    155
  • Abstract
    A "Dry LRU" mechanical architecture has been developed which minimizes the T/R Module and related component conductive path to the coolant without requiring coolant flow directly through the LRU. First designed and implemented by Lockheed Martin in an antenna for a Navy demonstration radar, the "Dry LRU" has since been re-designed and proven in the Volume Search Radar (VSR) EDM Antenna, part of the Dual Band Radar (DBR) destined for the Navy\´s new DDG 1000 Zumwalt Class Destroyers. The configuration of this LRU and the associated antenna level interfaces are described in this paper as well as the prototype and production thermal validation experiments used to verify the improved thermal performance. The "Dry LRU" is shown to be capable of providing thermal management for the high power T/R Modules required for the Navy latest Radar Systems.
  • Keywords
    antenna phased arrays; radar antennas; DBR; LRU; VSR; antenna array; dual band radar; line replaceable unit; thermal management; volume search radar; Antenna accessories; Coolants; Distributed Bragg reflectors; Dual band; Energy management; Production; Prototypes; Radar antennas; Thermal management; Thermal management of electronics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radar Conference, 2007 IEEE
  • Conference_Location
    Boston, MA
  • ISSN
    1097-5659
  • Print_ISBN
    1-4244-0284-0
  • Electronic_ISBN
    1097-5659
  • Type

    conf

  • DOI
    10.1109/RADAR.2007.374207
  • Filename
    4250301