MTF and DQE Measurements of Mercuric Iodide x-ray Imagers
Author :
Zentai, G. ; Partain, L.
Author_Institution :
Ginzton Technol. Center of Varian Med. Syst., Mountain View
fYear :
2007
fDate :
1-3 May 2007
Firstpage :
1
Lastpage :
6
Abstract :
The high sensitivity of HgI2 material for X-rays has been demonstrated previously. In this paper the focus is on the MTF (modulation transfer function), NPS (noise power spectra) and DQE (detective quantum efficiency) measurements and on the evaluations of a 13 cm x 13 cm size Hgl2 (mercuric iodide) coated X-ray imager with 127 mum pixel pitch. The imager was tested with 70 kVp X-ray beam and 21 mm Al filtration. Since a direct imager has no light scattering, a very high 45% MTF value was measured at the Nyquist frequency in comparison to about 16% of a Csl (indirect) detector with the same pixel pitch. Greater than 50% DQE(0) was also measured at a 35 nGy X-ray exposure. The first frame image lag was less than 8% when the imager was run at a 10 fr/s framerate. Some tests were also repeated with a high-energy 6 MeV X-ray source where similarly high MTF values were found. These new results demonstrate that the Hgl2 X-ray imagers can be used in cine mode, for low dose (fluoroscopic) imaging in medical, industrial and security applications giving low noise and high sensitivity performance. These new Hgl2 X-ray imagers may also allow decrease in the dose per medical X-ray examination. The result is a universal Hgl2 imager, which works for both the keV and the MeV energy ranges with excellent resolution.
Keywords :
X-ray imaging; mercury compounds; optical transfer function; radiology; DQE measurements; HgI2; MTF measurements; Nyquist frequency; X-ray beam; X-ray imagers; X-ray source; detective quantum efficiency; electron volt energy 6 MeV; fluoroscopic imaging; medical X-ray examination; mercuric iodide; modulation transfer function; noise power spectra; x-ray radiology; Biomedical imaging; Noise measurement; Pixel; Power measurement; Size measurement; Testing; Transfer functions; X-ray detection; X-ray detectors; X-ray imaging; Flat-Panel imaging arrays; imaging; imaging detectors; measurements with x-rays; mercuric iodide; polycrystalline; x-ray radiology;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference Proceedings, 2007. IMTC 2007. IEEE
Conference_Location :
Warsaw
ISSN :
1091-5281
Print_ISBN :
1-4244-0588-2
Type :
conf
DOI :
10.1109/IMTC.2007.379333
Filename :
4258041
Link To Document :
بازگشت