DocumentCode
2909571
Title
Test specimen shape considerations for the measurement of rotational core losses
Author
Alatawneh, Natheer ; Pillay, Pragasen
Author_Institution
Dept. of Electr. & Comput. Eng., Concordia Univ., Montreal, QC, Canada
fYear
2011
fDate
15-18 May 2011
Firstpage
1421
Lastpage
1426
Abstract
Accurate modeling of rotational core losses in AC electrical machines is necessary, theses losses occur at the roots of teeth and at the back of the slots in stator yokes of AC machines. In order to achieve a satisfactory model, the experimental measured data has to be as accurate as possible. The purpose of this paper is to propose a novel design of a magnetic circuit based on electromagnetic Halbach array, which generates a uniform flux density inside the specimen. Particular attention is paid to the test shape to allow accurate measurements.
Keywords
AC machines; loss measurement; magnetic circuits; stators; AC electrical machines; AC machines; electromagnetic Halbach array; magnetic circuit; rotational core losses measurement; stator yokes; teeth roots; test specimen shape; uniform flux density; Arrays; Core loss; Loss measurement; Magnetic circuits; Magnetic flux; Shape; Steel; Electrical steel; Halbach array; Magnetic materials; Rotational core losses;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Machines & Drives Conference (IEMDC), 2011 IEEE International
Conference_Location
Niagara Falls, ON
Print_ISBN
978-1-4577-0060-6
Type
conf
DOI
10.1109/IEMDC.2011.5994816
Filename
5994816
Link To Document