Title :
Stator teeth eddy-current loss analysis of interior permanent magnet machine during flux weakening
Author :
Li Qi ; Fan Tao ; Wen Xuhui ; Ye Li ; Tai Xiang ; Li Yong
Author_Institution :
Inst. of Electr. Eng., Beijing, China
Abstract :
Due to the rotor saliency of interior permanent magnet (IPM) machine, large harmonic eddy-current loss in the stator iron loss can be caused under flux-weakening operation, conspicuous impairing the output performance of the IPM machine. In this paper, a new stator teeth eddy-current loss analysis approach is proposed. Based on the analysis approach, the teeth eddy-current loss is divided to two parts, one part is caused by the synchronous air-gap flux density rotating synchronously with rotor, while the other part is induced by the asynchronous air-gap flux density. Two indexes are employed corresponding to the above mentioned eddy-current losses in teeth. The impact of magnet pole-arc coefficient and slot number per pair per pole on the indexes is investigated. The finite element analysis method is used to validate the proposed formulation.
Keywords :
eddy current losses; finite element analysis; permanent magnet machines; stators; IPM machine; asynchronous air-gap flux density; finite element analysis method; flux-weakening operation; harmonic eddy-current loss; interior permanent magnet machine; magnet pole-arc coefficient; rotor saliency; slot number; stator iron loss; stator teeth eddy-current loss analysis approach; synchronous air-gap flux density; Magnetic flux; Permanent magnet motors; Rotors; Stator windings; Synchronous motors; Windings;
Conference_Titel :
Electrical Machines and Systems (ICEMS), 2013 International Conference on
Conference_Location :
Busan
Print_ISBN :
978-1-4799-1446-3
DOI :
10.1109/ICEMS.2013.6713370