Abstract
This contribution explains insulation resistance and polarization of rotating machines through measurement results of Polarization Depolarization Current (PDC), or charging and discharging current, of machines having different types and conditions of insulation aging. It demonstrates why the Polarization Index (P.I.) cannot be used individually to judge insulation dryness and why the product of insulation resistance and capacitance is a better measure of insulation quality than the insulation resistance alone. But it is the combination of PDC, Capacitance ratio and Dielectric Dissipation Factor (DDF) which provides a decisive key in the diagnosis of global problems in machine insulation.
Keywords
capacitance; electric machines; machine insulation; polarisation; capacitance ratio; charging current; dielectric dissipation factor; discharging current; insulation aging; insulation capacitance; insulation dryness; insulation quality; insulation resistance; machine insulation; polarization depolarization current; polarization index; rotating machine polarization; Absorption; Capacitance; Dielectrics; Insulation; Partial discharges; Resistance; Time frequency analysis; absorption; capacitance; conduction; depolarization; dissipation factor; insulation; polarization; resistance;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation Conference (EIC), 2011
Conference_Location
Annapolis, MD
ISSN
pending
Print_ISBN
978-1-4577-0278-5
Electronic_ISBN
pending
Type
conf
DOI
10.1109/EIC.2011.5996156
Filename
5996156
Link To Document