• DocumentCode
    292811
  • Title

    Direct hierarchical symbolic transient analysis of linear circuits

  • Author

    Greenfield, Scott E. ; Hassoun, Marwan M.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Iowa State Univ., Ames, IA, USA
  • Volume
    1
  • fYear
    1994
  • fDate
    30 May-2 Jun 1994
  • Firstpage
    29
  • Abstract
    This paper presents a new direct and hierarchical symbolic transient analysis method for linear circuits. Three integration models were implemented symbolically with the trapezoidal method being the most efficient in terms of number of operations. An evaluation algorithm was implemented with a step sizing method based on estimation of truncation error. Test results show the success of the implementation and illustrate the automatic step reduction process necessary to retain numerical evaluation accuracy
  • Keywords
    circuit analysis computing; integration; linear network analysis; symbolic substitution; transient analysis; SCAPP; automatic step reduction process; direct analysis; evaluation algorithm; hierarchical symbolic transient analysis; integration models; linear circuits; step sizing; trapezoidal method; truncation error esimation; Algorithm design and analysis; Circuit analysis computing; Circuit simulation; Estimation error; Finite wordlength effects; Frequency domain analysis; Linear circuits; Partitioning algorithms; Sparse matrices; Transient analysis;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Circuits and Systems, 1994. ISCAS '94., 1994 IEEE International Symposium on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-1915-X
  • Type

    conf

  • DOI
    10.1109/ISCAS.1994.408747
  • Filename
    408747