  • Abstract
    The invention generally relates to dielectric testing of non-conductive bucket liners for mobile aerial man-lift equipment where two conductive shaped materials are placed on opposite sides of a dielectric material being tested. High voltage is applied to one of the conductive materials while a ground lead is attached to the other. Electrical current is measured from the grounded conductive material to identify any breakdown of the dielectric properties of the material being tested.
  • Keywords
    conducting materials; dielectric materials; electric current measurement; electrical safety; occupational safety; dielectric material; dielectric testing; dry testing; electrical current measurement; grounded conductive material; mobile aerial man-lift equipment; non-conductive bucket liners; Dielectrics; Flashover; Materials; Safety; Standards; Testing; Water pollution;