Abstract :
User-based estimation of intima-media thickness (IMT) of carotid arteries leads to subjectivity in its decision support systems, while being used as a cardiovascular risk marker. During automated computer-based decision support, we had developed segmentation strategies that follow three main courses of our contributions: (a) signal processing approach combined with snakes and fuzzy K-means (CULEXsa), (b) integrated approach based on seed and line detection followed by probability based connectivity and classification (CALEXsa), and (c) morphological approach with watershed transform and fitting (WS). We have extended this fusion concept by taking merits of these multiple boundaries, so called, Inter-Greedy (IG) approach. Starting from the technique with the overall least system error (the snake-based one), we iteratively swapped the vertices of the lumen-intima/media-adventitia (LI/MA) profiles until we minimized its overall distance with respect to ground truth. The fusion boundary was the IG boundary. The mean error of Inter-Greedy technique (evaluated on 200 images) yielded 0.32 ± 0.44 pixel (20.0 ± 27.5 μm) for the LI boundary (a 33.3% ± 5.6% improvement over initial best performing technique) and 0.21 ± 0.34 pixel (13.1 ± 21.3 μm) for MA boundary (a 32.3% ± 6.7% improvement). IMT measurement error for Greedy method was 0.74 ± 0.75 pixel (46.3 ± 46.9 μm), a 43.5% ± 2.4% improvement.
Keywords :
blood vessels; decision support systems; fuzzy systems; greedy algorithms; image segmentation; medical image processing; CULEXsa; automated computer-based decision support; cardiovascular risk marker; carotid segmentation boundaries; fitting; fusion boundary; fuzzy K-means; intergreedy technique; intima-media thickness; watershed transform; Carotid arteries; Image segmentation; Measurement errors; Pixel; Signal to noise ratio; Ultrasonic imaging; Algorithms; Artificial Intelligence; Carotid Arteries; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Pattern Recognition, Automated; Reproducibility of Results; Sensitivity and Specificity; Subtraction Technique; Tunica Intima; Tunica Media; Ultrasonography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE
Conference_Location :
Buenos Aires
ISSN :
1557-170X
Print_ISBN :
978-1-4244-4123-5
Type :
conf
DOI :
10.1109/IEMBS.2010.5626636
Filename :
5626636
Link To Document :
بازگشت