DocumentCode
2930486
Title
A novel techniques for step down converter implemented by high voltage operational amplifier
Author
Tripetch, Kittipong
Author_Institution
Div. of Electron. & Telecommun. Eng., Rajamangala Univ. of Technol. Suvarnabhumi, Muang, Thailand
fYear
2012
fDate
20-22 June 2012
Firstpage
287
Lastpage
292
Abstract
This paper introduces techniques which can be used to step down input voltage. It is different from traditional idea which use duty cycle concept. By using frequency domain concept low pass active filter can be used to step down input voltage. While high pass active filter can be used to step up output voltage. High precision supply voltage at 1mV step can be generated by the proposed techniques without the series resistor and switches more than 1000 pieces if the cut off frequency of the filter is accurate enough. If the input voltage is not as high as 15 volt, op-amp model LF353 can be used to implement step down converter.
Keywords
active filters; frequency-domain analysis; high-pass filters; low-pass filters; operational amplifiers; power convertors; LF353 op-amp model; duty cycle concept; frequency-domain concept; high-pass active filter; high-voltage operational amplifier; low-pass active filter; series resistor; step-down converter; voltage 1 mV; Active filters; Operational amplifiers; Phase locked loops; Pulse width modulation; Voltage control; Voltage measurement; Buck-Boost converter; Cuk converter; ac to dc converter; step up and down converter;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM), 2012 International Symposium on
Conference_Location
Sorrento
Print_ISBN
978-1-4673-1299-8
Type
conf
DOI
10.1109/SPEEDAM.2012.6264519
Filename
6264519
Link To Document