Abstract
The paper presents the design methodology and results of a transformer for backlight inverter (TFBI) supplying a cold cathode fluorescent lamp (CCFL). The backlight inverter adopts resonant behavior and operates by high frequency, and contains resonant tank circuit in its topology. The transformer functions as not only voltage rise but also an inductance in resonance bank, in which the second leakage inductance is dominant. So, TFBI should be analyzed and designed in different scheme from general transformer. The circuit coupled analysis and design, especially considering resonance behavior and ZVS, should be applied to TFBI for performance improvement of inverter overall as well as transformer itself. the authors propose the design of TFBI operated at the maximum efficiency point considering the circuit coupled magnetic field analysis and inverter drive method for ZVS. The design variables are turn number of coils, gap and parameters including inductances of transformer.
Keywords
invertors; liquid crystal displays; transformers; zero voltage switching; LCD backlight inverter; backlight unit; circuit coupled analysis; display industry; display technology; inverter drive method; inverter overall; leakage inductance; liquid crystal display; magnetic field analysis; resonance bank; resonant behavior; resonant tank circuit; transformer; turn number; zero voltage switching; Coupling circuits; Design methodology; Inductance; Inverters; Magnetic analysis; Magnetic circuits; Performance analysis; RLC circuits; Resonance; Zero voltage switching;
fLanguage
English
Publisher
ieee
Conference_Titel
Magnetics Conference, 2006. INTERMAG 2006. IEEE International
Conference_Location
San Diego, CA
Print_ISBN
1-4244-1479-2
Type
conf
DOI
10.1109/INTMAG.2006.375795
Filename
4261646
Link To Document