DocumentCode :
2940533
Title :
Control Study of Dual-BUCK Grid-Connected Inverter Based on Least Squares Algorithm
Author :
Wang Bin ; Yi Ling-Zhi
Author_Institution :
Coll. of Inf. Eng., Xiangtan Univ., Xiangtan, China
fYear :
2011
fDate :
25-28 March 2011
Firstpage :
1
Lastpage :
4
Abstract :
Photovoltaic inverter´s well all-weather featured and inherent characteristic it requires unique high reliability and high efficiency. In this paper, Dual-BUCK grid-connected inverter as the research objective, for the present study SPWM control and hysteresis current control algorithm shortcomings, a least squares fixed switching frequency hysteresis current control algorithm for Dual-BUCK grid connected inverter control is proposed. Simulation and experimental results prove the feasibility of the algorithm and high reliability, switching frequency stability, high efficiency of the system, and the output current has the same frequency as grid voltage.
Keywords :
PWM invertors; electric current control; least squares approximations; stability; SPWM control; dual-buck grid-connected inverter; grid voltage; hysteresis current control algorithm; least squares fixed switching frequency algorithm; switching frequency stability; Algorithm design and analysis; Current control; Fitting; Hysteresis; Inverters; Switches; Switching frequency;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power and Energy Engineering Conference (APPEEC), 2011 Asia-Pacific
Conference_Location :
Wuhan
ISSN :
2157-4839
Print_ISBN :
978-1-4244-6253-7
Type :
conf
DOI :
10.1109/APPEEC.2011.5749072
Filename :
5749072
Link To Document :
بازگشت