• DocumentCode
    294082
  • Title

    Study of MOV operator and motor characteristics to determine torque capability

  • Author

    Hussain, Drs B. ; Behera, A.K. ; Alsammarae, A.J.

  • Author_Institution
    KCI Eng. Consultants, Downers Grove, IL, USA
  • Volume
    3
  • fYear
    1994
  • fDate
    30 Oct-5 Nov 1994
  • Firstpage
    1126
  • Abstract
    Motor operated valves (MOV´s) used in the nuclear generating stations requires high thrust capability of a motor when demanded during an accident scenario. This paper specifically deals with the behavior and classification of motors used in AC MOVs. This paper also deals with a methodology that may be consistently applied to determine the realistic capability (that is rating) of the motor/operator. As an ongoing resolution to the NRC IEB 89-10 issue of the impact of degraded voltage condition and other environmental conditions on torque capability of the Motor Operated Valves (MOVs), the determination of appropriate motor torque capability is essential
  • Keywords
    AC motors; electric actuators; fission reactor cooling; fission reactor safety; valves; NRC IEB 89-10 issue; accident scenario; degraded voltage condition; high thrust capability; motor characteristics; motor operated valves; motor torque capability; motor/operator; nuclear generating stations; realistic capability; AC motors; Accidents; Actuators; Degradation; Manufacturing; Nuclear power generation; Pistons; Torque; Valves; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
  • Conference_Location
    Norfolk, VA
  • Print_ISBN
    0-7803-2544-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1994.474646
  • Filename