• DocumentCode
    2949673
  • Title

    Angle estimation of human femora in a three-dimensional virtual environment

  • Author

    Casciaro, Mariano E. ; Ritacco, Lucas E. ; Milano, Federico ; Risk, Marcelo ; Craiem, Damian

  • Author_Institution
    Favaloro Univ., Buenos Aires, Argentina
  • fYear
    2010
  • fDate
    Aug. 31 2010-Sept. 4 2010
  • Firstpage
    3946
  • Lastpage
    3949
  • Abstract
    The estimation of human femur morphology and angulation provide useful information for assisted surgery, follow-up evaluation and prosthesis design, cerebral palsy management, congenital dislocation of the hip and fractures of the femur. Conventional methods that estimate femoral neck anteversion employ planar projections because accurate 3D estimations require complex reconstruction routines. In a recent work, we proposed a cylinder fitting method to estimate bifurcation angles in coronary arteries and we thought to test it in the estimation of femoral neck anteversion, valgus and shaft-neck angles. Femora from 10 patients were scanned using multisliced computed tomography. Virtual cylinders were fitted to 3 regions of the bone painted by the user to automatically estimate the femoral angles. Comparisons were made with a conventional manual method. Inter- and intra-reading measurements were evaluated for each method. We found femoral angles from both methods strongly correlated. Average anteversion, neck-shaft and valgus angles were 17.5°, 139.5°, 99.1°, respectively. The repeatability and reproducibility of the automated method showed a 5-fold reduction in inter- and intra-reading variability. Accordingly, the coefficients of variation for the manual method were below 25% whereas for the automated method were below 6%. The valgus angle assessment was globally the most accurate with differences below 1°. Maximum distances from true surface bone points and fitting cylinders attained 6 mm. The employment of virtual cylinders fitted to different regions of human femora consistently helped to assess true 3D angulations.
  • Keywords
    angular measurement; biomedical measurement; bone; computerised tomography; image segmentation; medical image processing; virtual reality; angle estimation; bone; cylinder fitting method; femoral neck anteversion angle; femoral shaft-neck angle; femoral valgus angle; femur segmentation; human femur angulation; human femur morphology; interreading variability; intrareading variability; multisliced computed tomography; three-dimensional virtual environment; virtual cylinders; Bones; Computed tomography; Estimation; Humans; Manuals; Neck; Three dimensional displays; Femur; Humans; Imaging, Three-Dimensional; Reproducibility of Results; User-Computer Interface;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE
  • Conference_Location
    Buenos Aires
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4123-5
  • Type

    conf

  • DOI
    10.1109/IEMBS.2010.5627701
  • Filename
    5627701