Abstract
The BNM-LCIE Thompson Lampard Calculable Capacitance (TLCC) has been taken apart for improvements between 1994 and 1997. Influencing parameters were determined and/or corrected: parallelism of the electrodes, end effects, dimensions of a compensating spike and effect of its lateral displacement. With these improvements and by using a new interferometer, the realization of the farad is achieved with an uncertainty (not taking into account the frequency dependance of the TLCC) equal to 3 10/sup -8/ (1/spl sigma/).
Keywords
capacitance measurement; electrodes; error compensation; measurement standards; measurement uncertainty; units (measurement); BNM-LCIE Thompson Lampard Calculable Capacitance; Lampard theorem; Michelson interferometer; compensating spike dimensions; cylindrical defects; electrodes parallelism; end effects; farad realization; five horizontal electrode bars standard; fringes interpolation; lateral displacement; linearity; ratio bridge; uncertainty; Bars; Bridge circuits; Capacitance; Capacitors; Electrodes; Equations; Fasteners; Frequency; Uncertainty; Vacuum systems;