• DocumentCode
    2961748
  • Title

    Realization of the farad at BNM-LCIE

  • Author

    Trapon, G. ; Thevenot, O. ; Lacueille, J.C. ; Geneves, G.

  • Author_Institution
    Lab. Central des Ind. Electr., Bur. Nat. de Metrol., Fontenay-aux-Roses, France
  • fYear
    1998
  • fDate
    6-10 July 1998
  • Firstpage
    448
  • Lastpage
    449
  • Abstract
    The BNM-LCIE Thompson Lampard Calculable Capacitance (TLCC) has been taken apart for improvements between 1994 and 1997. Influencing parameters were determined and/or corrected: parallelism of the electrodes, end effects, dimensions of a compensating spike and effect of its lateral displacement. With these improvements and by using a new interferometer, the realization of the farad is achieved with an uncertainty (not taking into account the frequency dependance of the TLCC) equal to 3 10/sup -8/ (1/spl sigma/).
  • Keywords
    capacitance measurement; electrodes; error compensation; measurement standards; measurement uncertainty; units (measurement); BNM-LCIE Thompson Lampard Calculable Capacitance; Lampard theorem; Michelson interferometer; compensating spike dimensions; cylindrical defects; electrodes parallelism; end effects; farad realization; five horizontal electrode bars standard; fringes interpolation; lateral displacement; linearity; ratio bridge; uncertainty; Bars; Bridge circuits; Capacitance; Capacitors; Electrodes; Equations; Fasteners; Frequency; Uncertainty; Vacuum systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1998 Conference on
  • Conference_Location
    Washington, DC, USA
  • Print_ISBN
    0-7803-5018-9
  • Type

    conf

  • DOI
    10.1109/CPEM.1998.699997
  • Filename
    699997