Abstract
The flatness and frequency dependence of the i=2 and 4 quantized Hall resistance plateaux have been investigated. It was observed that for frequencies up to 6.4 kHz, a flat region exists at the centre of the plateaux where the resistance is constant to 2/spl times/10/sup -8/, and its value has a linear frequency dependence of 0.1 ppm/kHz.
Keywords
bridge circuits; electric resistance measurement; measurement standards; quantum Hall effect; resistors; 6.4 kHz; AC coaxial bridge; AC quantized Hall resistance measurement; AC resistance standard; flatness; frequency dependence; linear frequency dependence; quadrifilar resistors; quantized Hall resistance plateaux; ratio bridge; Bridges; Coaxial components; Current measurement; Electrical resistance measurement; Frequency dependence; Frequency measurement; Laboratories; Productivity; Resistors; Standards Board;