DocumentCode
2969306
Title
Analysis of current transfer process during the open operating in large current vacuum interrupters with dual-contact
Author
Li Yu ; Shun Yuan ; Feng Li
Author_Institution
Dept. of Electr. Eng., Shenyang Inst. of Eng., Shenyang, China
fYear
2012
fDate
2-7 Sept. 2012
Firstpage
197
Lastpage
200
Abstract
A new type of “dual-contact” structure of vacuum interrupter is proposed in the paper. It consists of main contact and arc contact, which are used to carry rated current and break short circuit current, respectively. During the closing/opening of vacuum circuit breaker, arc contact is first closed and post breaking, however, main contact is post closed and first breaking. So there must be the current transfer process. In this paper, during the breaking process of vacuum circuit breaker, a model of current transfer is used in the investigation of current transfer, and the maximum possible current transfer time is obtained. This analysis is helpful to the research of large current vacuum interrupters with dual-contact.
Keywords
arcs (electric); electrical contacts; short-circuit currents; vacuum interrupters; arc contact; breaking process; current transfer process analysis; dual-contact structure; large current vacuum interrupters; short circuit current; Circuit breakers; Integrated circuit modeling; Interrupters; Resistance; SPICE; Short circuit currents; Springs;
fLanguage
English
Publisher
ieee
Conference_Titel
Discharges and Electrical Insulation in Vacuum (ISDEIV), 2012 25th International Symposium on
Conference_Location
Tomsk
ISSN
1093-2941
Print_ISBN
978-1-4673-1263-9
Electronic_ISBN
1093-2941
Type
conf