DocumentCode :
2971267
Title :
FEM analysis and experimental verification of the ultrasonic transducer for thermosonic flip-chip bonding machine
Author :
Huang, Yi-Cheng ; Hsiao, Fu-Sheng
Author_Institution :
Dept. of Mechatron. Eng., Nat. Changhua Univ. of Educ., Changhua, Taiwan
fYear :
2009
fDate :
22-24 June 2009
Firstpage :
773
Lastpage :
777
Abstract :
The thermosonic flip-chip bonding technology operates in lower temperature, bonding force, and less bonding time than wire bonding. Improving the bonding efficiency of ultrasonic transducers plays an important role for bettering bonding process in gold-to-gold interfaces. Analysis of the transducer tool both in mechanical vibration and electrical performance is great concern. The commercial package GID & ATILA software is used for simulation first. Finding the best resonance frequency of the transducer tool was determined with LCR impedance meter experimentally. In this paper, we illustrate the in-laboratory thermosonic flip-chip bonding machine systematically and some characteristics of an ultrasonic transducer are investigated.
Keywords :
finite element analysis; flip-chip devices; lead bonding; tape automated bonding; ultrasonic transducers; FEM analysis; bonding force; commercial package GID & ATILA software; impedance meter; resonance frequency; thermosonic flip-chip bonding machine; ultrasonic transducer; wire bonding; Bonding forces; Bonding processes; Packaging machines; Performance analysis; Resonance; Software packages; Temperature; Ultrasonic transducers; Vibrations; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Information and Automation, 2009. ICIA '09. International Conference on
Conference_Location :
Zhuhai, Macau
Print_ISBN :
978-1-4244-3607-1
Electronic_ISBN :
978-1-4244-3608-8
Type :
conf
DOI :
10.1109/ICINFA.2009.5205025
Filename :
5205025
Link To Document :
بازگشت