• DocumentCode
    2979743
  • Title

    Capacitive micromachined ultrasonic transducers (CMUTs) with isolation posts

  • Author

    Huang, Yongli ; Haeggström, Edward O. ; Zhuang, Xuefeng ; Ergun, Arif S. ; Khuri-Yakub, Butrus T.

  • Author_Institution
    Edward L. Ginzton Lab., Stanford Univ., CA, USA
  • Volume
    3
  • fYear
    2004
  • fDate
    23-27 Aug. 2004
  • Firstpage
    2223
  • Abstract
    We report on a capacitive micromachined ultrasonic transducer (CMUT) featuring isolation posts (PostCMUT) to solve a device reliability problem caused by charging during fabrication and operation, and to extend the device operation range beyond collapse voltage. The PostCMUTs were fabricated using a newly developed process based on the wafer-bonding technique. Paired tests showed the superior reliability characteristics of the PostCMUT design compared to those of earlier CMUT designs. The PostCMUTs showed no hysteresis during membrane-post contact.
  • Keywords
    capacitive sensors; dielectric hysteresis; micromechanical devices; piezoelectric transducers; reliability; ultrasonic transducers; wafer bonding; CMUT; capacitive charging; capacitive micromachined ultrasonic transducer; collapse voltage; device reliability problem; hysteresis; isolation posts; piezoelectric transducers; wafer-bonding technique; Biomembranes; Dielectrics; Electrodes; Fabrication; Hysteresis; Laboratories; Silicon; Testing; Ultrasonic transducers; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2004 IEEE
  • ISSN
    1051-0117
  • Print_ISBN
    0-7803-8412-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2004.1418281
  • Filename
    1418281