Abstract :
This paper shows the benefits of synchronous multichannel PD measurements. Different methods of evaluation as 3PARD, multi-site PD decoupling and multi-frequency PD decoupling are presented in theory and supported by application examples as PD measurements on power transformers and high voltage XLPE cable systems. These advanced evaluation techniques require a fully synchronized multi-channel PD measuring system, also detailed and presented in this paper.
Keywords :
XLPE insulation; partial discharge measurement; power cable insulation; power transformer insulation; high voltage XLPE cable systems; multifrequency PD decoupling; multisite PD decoupling; power transformers; synchronous multichannel PD measurements; Frequency measurement; Optical fiber cables; Optical filters; Partial discharge measurement; Partial discharges; Particle measurements; Position measurement; Pulse measurements; Software measurement; Testing;