• DocumentCode
    2998313
  • Title

    Applicability of the GP Device to the Circle of Willis Arteries by Using a Mathematical Model

  • Author

    Romero, G. ; Martinez, M.L. ; Felez, J. ; Pearce, G. ; Perkinson, N.D.

  • Author_Institution
    ETSI Eng., Tech. Univ. of Madrid, Madrid, Spain
  • fYear
    2011
  • fDate
    March 30 2011-April 1 2011
  • Firstpage
    48
  • Lastpage
    53
  • Abstract
    According to the World Health Organization, 15 million people suffer stroke worldwide each year, of these, 5 million die and 5 million are permanently disabled. Stroke is therefore a major cause of mortality world-wide. The majority of strokes are caused by a blood clot that occludes an artery in the brain, and although thrombolytic agents such as Alteplase are used to dissolve clots that arise in the arteries of the brain, there are limitations on the use of these thrombolytic agents. However over the past decade, other methods of treatment have been developed which include Thrombectomy Devices e.g. the ´GP´ Thrombus Aspiration Device (´GP´ TAD). Such devices may be used as an alternative to thrombolytics or in conjunction with them to extract blood clots in arteries such as the middle cerebral artery of the midbrain brain, and the posterior inferior cerebellar artery (PICA) of the posterior aspect of the brain. In this paper, we mathematically model the removal of blood clots using the ´GP´ TAD from selected arteries of the brain where blood clots may arise taking into account factors such as the resistances, compliances and inertances effects. Such mathematical modelling may have potential uses in predicting the pressures necessary to extract blood clots of given lengths, and masses from arteries in the Circle of Willis - posterior circulation of the brain.
  • Keywords
    biomedical equipment; blood vessels; brain; diseases; haemodynamics; patient treatment; physiological models; Alteplase; Circle of Willis artery; GP Thrombus Aspiration Device; Thrombectomy Devices; World Health Organization; blood clot; brain artery; mathematical model; middle cerebral artery; posterior brain circulation; posterior inferior cerebellar artery; stroke; thrombolytic agents; Arteries; Catheters; Coagulation; Fluids; Force; Friction; Mathematical model; Biomedical engineering; Circle of Willis; Simulation; Thrombectomy Device;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer Modelling and Simulation (UKSim), 2011 UkSim 13th International Conference on
  • Conference_Location
    Cambridge
  • Print_ISBN
    978-1-61284-705-4
  • Electronic_ISBN
    978-0-7695-4376-5
  • Type

    conf

  • DOI
    10.1109/UKSIM.2011.19
  • Filename
    5754206