DocumentCode :
3013344
Title :
Research on insulation state monitoring network technique for vessel electric network
Author :
Hanhong, Jiang ; Guoshun, Xu ; Qing, Li
Author_Institution :
Dept. of Electr. Eng., Naval Univ. of Eng., Wuhan
Volume :
3
fYear :
2005
fDate :
29-29 Sept. 2005
Firstpage :
2250
Abstract :
Insulation state monitoring method of vessel electric network is analyzed. A method of locating insulation fault branches of AC and DC system is presented. It solves the influence of distributed capacitor to the ground of electric network branches when monitoring insulation, and also improves sensitivity and accuracy. A insulation state monitoring network system for vessel electric network is designed. Thereby, monitoring points can be selected. Distributed monitoring and real-time on-line remote monitoring can be implemented
Keywords :
computerised monitoring; distribution networks; insulation; marine engineering; power capacitors; power engineering computing; ships; transmission networks; distributed capacitor; insulation fault location; insulation state monitoring network technique; real-time online remote monitoring; vessel electric network; Capacitance; Computerized monitoring; Dielectrics and electrical insulation; Electric resistance; Electronic mail; Equivalent circuits; Frequency; Insulation life; Joining processes; Remote monitoring; insulation resistance; monitoring network; vessel electric network;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2005. ICEMS 2005. Proceedings of the Eighth International Conference on
Conference_Location :
Nanjing
Print_ISBN :
7-5062-7407-8
Type :
conf
DOI :
10.1109/ICEMS.2005.202968
Filename :
1575165
Link To Document :
بازگشت