Abstract :
This paper describes the 600 MW Supercritical Boiler´s Main Steam Temperature Control method and analysis the characteristic of the method. Operation information show that the main steam temperature overheating appears commonly in actual operation process. In this paper, 600MW super-critical boiler´s flue gas tube wall temperature was tested by setting probes in the furnace. The experimental results shown that the tube wall temperature changes swiftly with the load variation. There is significant temperature bias between testing cells at same super-heater stage. On this basis, a new control strategy was derived for 600 MW Supercritical Boiler´s Main Steam.
Keywords :
boilers; flue gases; steam; temperature control; control strategy; flue gas tube wall temperature; furnace; load variation; main steam temperature control; main steam temperature overheating; power 600 MW; probes; super-heater stage; supercritical boiler main steam; temperature bias; testing cells; Boilers; Cooling; Electron tubes; Fuels; Temperature distribution; Temperature measurement; Control; Main Steam Temperature; Supercritical Boiler; experiment;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Control Engineering (ICECE), 2010 International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-6880-5
Type :
conf
DOI :
10.1109/iCECE.2010.1427
Filename :
5631580
Link To Document :
بازگشت