    In vitro measurement of ambient pressure changes using a realistic clinical setup

  • Author

    Andersen, Klaus Scheldrup ; Jensen, Jørgen Arendt

  • Author_Institution
    Dept. of Electr. Eng., Tech. Univ. of Denmark, Lyngby
  • fYear
    2008
  • fDate
    2-5 Nov. 2008
  • Firstpage
    1096
  • Lastpage
    1099
  • Abstract
    Many attempts to find a non-invasive procedure to measure the local blood pressure have been made. In the last decade independent experiments have indicated that the amplitude of the subharmonic response from contrast agents is sensitive to the ambient pressure. This paper presents a new experimental setup for measuring the acoustic response of a contrast agent when subjected to ambient over pressure. The setup is very flexible offering completely arbitrary excitation and data acquisition, fast and accurate ambient pressure control, and precise timing. More importantly, it resembles a realistic clinical setup using a single array transducer for transmit and receive. In this experiment, the acoustic response of SonoVue (Bracco, Milano, Italy) was measured twice at six different ambient hydrostatic pressures in the interval 0 to 25 kPa with an accuracy within 0.5 kPa. The acquired RF data was filtered and beamformed before further processing. To compensate for variations in bubble response and to make the estimates more robust, the relation between the energy of the subharmonic and the fundamental component was chosen as a measure over the subharmonic peak amplitude. The results of the first measurement sequence show an ambient pressure sensitivity of 0.42 dB/kPa having a linear correlation coefficient of 0.94. In the second sequence, a sensitivity of 0.41 dB/kPa with a correlation coefficient of 0.89 was found.
  • Keywords
    biomedical transducers; biomedical ultrasonics; blood pressure measurement; bubbles; data acquisition; pressure control; ultrasonic transducer arrays; RF data beamforming; RF data filtering; SonoVue acoustic response; acoustic contrast agent response; ambient hydrostatic pressure; ambient pressure control; ambient pressure sensitivity; blood pressure measurement; bubble response; in vitro ambient pressure change measurement; linear correlation coefficient; pressure 0 kPa to 25 kPa; single array transducer; subharmonic energy-fundamental component relation; subharmonic peak amplitude; ultrasound data acquisition; Acoustic measurements; Acoustic transducers; Amplitude estimation; Blood pressure; Data acquisition; In vitro; Pressure control; Pressure measurement; Radio frequency; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2008. IUS 2008. IEEE
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-2428-3
  • Electronic_ISBN
    978-1-4244-2480-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2008.0264
  • Filename
    4803335