    A model-based displacement outlier removal algorithm for ultrasonic temperature estimation

  • Author

    Ye, Guoliang ; Noble, J. Alison ; Smith, Penny Probert ; Hsieh, Chang-yu

  • Author_Institution
    Biomed. Image Anal. Group, Univ. of Oxford, Oxford
  • fYear
    2008
  • fDate
    2-5 Nov. 2008
  • Firstpage
    2080
  • Lastpage
    2083
  • Abstract
    In using ultrasound echo strain to estimate temperature for monitoring HIFU thermal therapy, block matching algorithms are used to estimate the displacement over two image frames. However, due to the image distortion and artifacts over frames, the displacement will be estimated with outliers which will seriously bias echo strain estimation. This paper introduces a novel model-based algorithm to constrain the displacement estimation. The displacement is initially estimated using correlation analysis and then the outliers on the displacement data will be removed by examining the difference between the data and a parameterised displacement model. Finally the removed outliers will be replaced by the expected values from the model or the interpolation from neighboring normal data. Experimental results on the data form a uniformly heated gel phantom and a HIFU exposed bovine liver showed that the model-based algorithm successfully removed the displacement outliers and was also superior to a median filter which is a common method. In conclusion, the model-based algorithm introduce a displacement model as prior information to remove displacement outliers, which shows great potential to improve the ultrasonic temperature estimation from the ultrasound images distorted by HIFU exposures.
  • Keywords
    acoustic correlation; biomechanics; biomedical ultrasonics; hyperthermia; image matching; interpolation; liver; medical image processing; patient monitoring; phantoms; ultrasonic therapy; HIFU thermal therapy monitoring; block matching algorithms; bovine liver; correlation analysis; displacement estimation; image artifacts; image distortion; image frames; interpolation; model-based displacement outlier removal; parameterised displacement model; ultrasonic temperature estimation; ultrasound echo strain; ultrasound images; uniformly heated gel phantom; Bovine; Capacitive sensors; Filters; Imaging phantoms; Interpolation; Liver; Medical treatment; Temperature measurement; Temperature sensors; Ultrasonic imaging; HIFU; displacement outlier; echo strain; temperature model; ultrasound temperature estimation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2008. IUS 2008. IEEE
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-2428-3
  • Electronic_ISBN
    978-1-4244-2480-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2008.0514
  • Filename
    4803503