DocumentCode :
3045635
Title :
A compensation method of phase-shift error on reactive power measurement
Author :
Guo Songlin ; Qiang, Fu ; Xianzhuang, Meng
Author_Institution :
Coll. of Electr. & Inf. Eng., Heilongjiang Inst. of Sci. & Technol., Harbin, China
Volume :
2
fYear :
2012
fDate :
18-20 May 2012
Firstpage :
626
Lastpage :
629
Abstract :
A digital phase-shift error´s compensation method on reactive power measure in the multi- function electric energy meter is presented in the paper. The compensation result is analyzed, and the related design method is discussed. And the mathematic formula of phase-shift error´s compensation is put forward in the paper.
Keywords :
power measurement; power meters; reactive power; compensation method; digital phase shift error; multifunction electric energy meter; reactive power measurement; Energy measurement; Frequency measurement; Measurement uncertainty; Phase measurement; Power measurement; Reactive power; digital phase-shift; error correction; measurement of reactive power;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Measurement, Information and Control (MIC), 2012 International Conference on
Conference_Location :
Harbin
Print_ISBN :
978-1-4577-1601-0
Type :
conf
DOI :
10.1109/MIC.2012.6273371
Filename :
6273371
Link To Document :
بازگشت