DocumentCode :
3046573
Title :
On Energy Recovery Possibility at Test Facility of Generator Sets
Author :
Caramia, P. ; Di Perna, C. ; Minutillo, M. ; Varilone, P. ; Verde, P.
Author_Institution :
Univ. of Cassino, Cassino
fYear :
2007
fDate :
21-23 May 2007
Firstpage :
639
Lastpage :
642
Abstract :
Actual Standards require specific tests on the generator sets to be overcome before introducing them into the market. During these tests, synchronous machines produce electrical energy that, in traditional test facilities, is dissipated on resistors. In this paper the realization of a no dissipative test facility able to recover this produced electrical energy is proposed. Energy recovery estimation is based on real data of an existing generator set manufacturer.
Keywords :
synchronous generators; dissipative test facility; electrical energy; energy recovery estimation; generator set; synchronous machine; AC generators; Erbium; ISO standards; Manufacturing; Power generation; Production facilities; Reactive power; Synchronous machines; System testing; Test facilities; Energy recovery; Generator set;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Clean Electrical Power, 2007. ICCEP '07. International Conference on
Conference_Location :
Capri
Print_ISBN :
1-4244-0631-5
Type :
conf
DOI :
10.1109/ICCEP.2007.384304
Filename :
4272475